TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 332 of 1558

TM 9-2320-366-20-4 7-134. STARTER TO SHUNT 24 VDC CABLE REPLACEMENT (CONT) NOTE • Both clamps are removed the same way. One shown. • Remove plastic cable ties as required. • Step (2) requires the aid of an assistant. (2) Remove self-locking nut (5), screw (6), and clamp (7) from frame rail (8). Discard self-locking nut. (3) Remove starter to shunt 24 vdc cable (9) from clamp (7). (4) Perform steps (2) and (3) on remaining clamp. (5) Remove screw (10), lockwasher (11), and terminal lug TL45 (12) from lower shunt terminal (13). Discard lockwasher. NOTE Note routing of starter to shunt 24 vdc cable prior to removal. (6) Remove starter to shunt 24 vdc cable (9) from vehicle. b. Installation. (1) Position starter to shunt 24 vdc cable (1) on vehicle. (2) Install terminal lug TL45 (2) on lower shunt terminal (3) with lockwasher (4) and screw (5). 7-662