TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 307 of 1558

TM 9-2320-366-20-4 (14) Remove self-locking nut (22), screw (23), clamp (24), and 100 amp reverse polarity relay to PDP 24 vdc cable (25) from frame rail (26). Discard self-locking nut. (15) Remove 100 amp reverse polarity relay to PDP 24 vdc cable (25) from clamp (24). (16) Remove self-locking nut (27), washer (28), screw (29), and washer (30) from clamps (31 and 32). Discard self- locking nut. (17) Remove 100 amp reverse polarity relay to PDP 24 vdc cable (25) from clamp (31). (18) Remove 100 amp reverse polarity relay to PDP 24 vdc cable (25) from cab (33). 7-639