TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 299 of 1558

TM 9-2320-366-20-4 7-130. 100 AMP REVERSE POLARITY RELAY TO POWER DISTRIBUTION (PDP) PANEL 12 VDC CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Batteries disconnected (para 7-57). PDP cover removed (para 16-2). Spare tire lowered (TM 9-2320-366-10-2). Lower radiator fan shroud removed (para 6-4). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C) Socket Set, Socket Wrench (Item 34, Appendix C) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Nut, Self-Locking (2) (Item 153, Appendix G) Lockwasher (Item 96, Appendix G) Lockwasher (Item 84, Appendix G) a. Removal. (1) Remove three screws (1) and washers (2) from PDP (3). (2) Remove three screws (4) from PDP (3). (3) Lift PDP (3) outward to gain access. NOTE Remove plastic cable ties as required. (4) Remove screw (5), lockwasher (6), terminal lug TL41 (7), and four terminal lugs (8) from PDP (3). Discard lockwasher. (5) Position four terminal lugs (8) on PDP (3) with screw (5). 7-631