TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 271 of 1558
TM 9-2320-366-20-4 (8) Close cover (12) on junction box (13). (9) Tighten four screws (14) on junction box (13). NOTE Install plastic cable ties as required. (10) Connect connector (15) to telescope out lockout solenoid (16). c. Follow-On Maintenance. (1) Connect batteries (para 7-57). (2) Operate MHC and check telescope out lockout operation (TM 9-2320-366-10-2). End of Task. 7-603