TM 9-2320-366-20-4 7-122. M1089 TELESCOPE OUT LOCKOUT SOLENOID CABLE REPLACEMENT (CONT) b. Installation. (1) Install telescope out lockout solenoid cable (1) through compression nut (2), washer (3), and connector (4). (2) Install compression nut (2) on connector (4). (3) Install quick disconnect terminal (5) on black wire (6). (4) Install terminal lug (7) on white wire (8). (5) Install quick disconnect terminal (5) on ground strip (9) position 10. (6) Install terminal lug (7) on terminal block (10) position 19 with screw (11). (7) Apply varnish to quick disconnect terminal (5) and terminal lug (7). 7-602