TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 176 of 1558
TM 9-2320-366-20-4 7-103. M1084/M1086 TELESCOPE OUT SOLENOID CABLE REPLACEMENT (CONT) (10) Close cover (14) on junction box (15). (11) Tighten four screws (16) on junction box (15). NOTE Install plastic cable ties as required. (12) Connect connector (17) to telescope out solenoid (18). c. Follow-On Maintenance. (1) Connect batteries (para 7-57). (2) Operate MHC and check telescope out operation (TM 9- 2320-366-10-1). End of Task. 7-504