TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 172 of 1558

TM 9-2320-366-20-4 7-102. M1084/M1086 TELESCOPE OUT LOCKOUT SOLENOID CABLE REPLACEMENT (CONT) (10) Close cover (14) on junction box (15). (11) Tighten four screws (16) on junction box (15). NOTE Install plastic cable ties as required. (12) Connect connector (17) to telescope out lockout solenoid (18). c. Follow-On Maintenance. (1) Connect batteries (para 7-57). (2) Operate MHC and check telescope out lockout operation (TM 9-2320-366-10-1). End of Task. 7-500