TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 144 of 1558

TM 9-2320-366-20-4 7-95. M1084/M1086 OVERLOAD LOCKOUT CABLE REPLACEMENT (CONT) b. Installation. (1) Position overload lockout cable (1) through clamp (2). (2) Route overload lockout cable (1) through clamp (3), compression nut (4), and connector (5). (3) Install compression nut (4) on connector (5). (4) Tighten two screws (6) on clamp (3). (5) Tighten nut (7) on clamp (2). (6) Install quick disconnect terminal (8) on green wire (9). (7) Install terminal lug (10) on black wire (11). (8) Install terminal lug (12) on red wire (13). (9) Install terminal lug (14) on white wire (15). (10) Install quick disconnect terminal (8) on ground strip (16) position 8. (11) Install terminal lug (10) on terminal block (17) position 6 with screw (18). (12) Install terminal lug (12) on terminal block (19) position 25 with screw (18). (13) Install terminal lug (14) on terminal block (19) position 28 with screw (18). (14) Apply varnish to quick disconnect terminal (8) and terminal lugs (10, 12, and 14). 7-472