TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 995 of 1396

TM 9-2320-366-20-3 (2) Remove lock ring (3) and audible alarm (4) from instrument panel assembly (5). NOTE • Tag wires and connection points prior to disconnecting. • Perform step (3) on M1084, M1086, M1088, and M1089. (3) Remove two screws (6) and terminal lugs TL161 (7) and TL160 (8) from audible alarm (4). NOTE Perform steps (4) and (5) on all models except M1084, M1086, M1088, and M1089. (4) Remove two screws (6) and terminal lugs TL161 (7) and TL178 (8) from audible alarm (4). (5) Remove screw (9) and TL160 (10) from audible alarm (4). b. Installation. NOTE Perform steps (1) and (2) on all models except M1084, M1086, M1088, and M1089. (1) Install terminal lug TL160 (1) on audible alarm (2) with screw (3). (2) Install terminal lugs TL161 (4) and TL178 (5) on audible alarm (2) with two screws (6). NOTE Perform step (3) on M1084, M1086, M1088, and M1089. (3) Install terminal lugs TL160 (5) and TL161 (4) on audible alarm (2) with two screws (6). (4) Install audible alarm (2) in instrument panel assembly (7) with lock ring (8). Change 1 7-242.1/(7-242.2 Blank)