TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 944 of 1396
TM 9-2320-366-20-3 7-32. REMOTE CONTROL UNIT REPAIR (CONT) WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (7) Apply adhesive to the first 2 to 5 threads of mounting studs (11). (8) Position four self-locking nuts (12) on boom up/down controller (9). (9) Tighten four self-locking nuts (12) to 14 lb-in. (2 N·m). NOTE Adhesive requires 24 hours to cure. (10) Spread excess adhesive over heads of four self-locking nuts (12). e. Harness Removal. NOTE • All four controllers are removed for harness removal. • All four controllers are removed the same way. Boom Up/Down controller shown. (1) Remove four self-locking nuts (1) from boom up/down controller (2). Discard self-locking nuts. (2) Remove boom up/down controller (2) from REMOTE CONTROL UNIT (3) until connector (4) is accessible. (3) Disconnect connector (4) from boom up/down controller (2). (4) Remove adhesive from seating surface (5). 7-194 Change 1