TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 943 of 1396
TM 9-2320-366-20-3  d. Toggle Switch Installation.  (1) Connect four wires (1) to toggle switch (2).  NOTE  Keyway of toggle switch aligns with keyway  slot in mounting hole.  (2) Position toggle switch (2) in mounting hole (3).  (3) Install switch guard cover (4) on toggle switch (2) with  nylon washer (5) and nut (6).  WARNING  Adhesives, solvents, and sealing com-  pounds can burn easily, can give off  harmful vapors, and are harmful to skin  and clothing. Keep away from open fire  and use in a well-ventilated area. If  adhesive, solvent, or sealing compound  gets on skin or clothing, wash  immediately with soap and water. Failure  to comply may result in injury to  personnel.  (4) Apply adhesive to seating surface (7).  (5) Connect connector (8) to boom up/down controller (9).  (6) Position boom up/down controller (9) in REMOTE  CONTROL UNIT (10).  Change 1 7-193