TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 943 of 1396
TM 9-2320-366-20-3 d. Toggle Switch Installation. (1) Connect four wires (1) to toggle switch (2). NOTE Keyway of toggle switch aligns with keyway slot in mounting hole. (2) Position toggle switch (2) in mounting hole (3). (3) Install switch guard cover (4) on toggle switch (2) with nylon washer (5) and nut (6). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (4) Apply adhesive to seating surface (7). (5) Connect connector (8) to boom up/down controller (9). (6) Position boom up/down controller (9) in REMOTE CONTROL UNIT (10). Change 1 7-193