TM 9-2320-366-20-3 (7) Lift dust boot (14) on terminal lug TL80 (15). (8) Remove nut (16), lockwasher (17), and terminal lug TL80 (15) from 100 amp reverse polarity relay (9). Discard lockwasher. (9) Lift terminal cover (18) on terminal lugs TL1 (19), TL37 (20) and TL36 (21). (10) Remove nut (22), lockwasher (23), and terminal lugs TL1 (19), TL37 (20), and TL36 (21) from 100 amp reverse polarity relay (9). Discard lockwasher. (11) Remove six self-locking nuts (24), spring washers (25), screws (26), and 100 amp reverse polarity relay (9) from bracket (27). Discard spring washers and self-locking nuts. b. Installation. (1) Position 100 amp reverse polarity relay (1) on bracket (2) with six screws (3), spring washers (4), and self-locking nuts (5). (2) Tighten six screws (3) to 60-72 lb-in. (7-8 N·m). 7-185