TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 928 of 1396
TM 9-2320-366-20-3 7-28. M1089 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT) (23) Install overload shutdown system cable (46) in junction box (1) with four screws (47), lockwashers (48), and nuts (49). (24) Install quick disconnect terminal (50) on ground strip (12) position 3. (25) Install four terminal lugs (51) on terminal block (17) positions 1, 17 and 19 with three screws (52). (26) Install boom down lockout solenoid cable (53) in junction box (1) with conduit nut (54). 7-178