TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 921 of 1396

TM 9-2320-366-20-3 NOTE Perform steps (11) through (14) on junction boxes that have not had modification kit installed. (11) Install shutdown relay (30) on bracket (31) with three washers (32), lockwashers (33), and nuts (34). (12) Install bracket (31) on junction box (2) with three rivets (35). (13) Install shrink tubing (36) over ends of five wires (37) and solder ends on shutdown relay (30) positions 1 through 5. (14) Shrink the tubing over ends of all relay pins. (15) Install diode assembly (38) on junction box (2) with two rivets (39). (16) Connect three quick disconnect terminals (40) on diode assembly (38). (17) Apply varnish to quick disconnect terminals (40). Change 1 7-172.1/(7-172.2 Blank)