TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 902 of 1396
TM 9-2320-366-20-3 7-27. M1084/M1086 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT) (20) Install left proximity sensor cable (41) in junction box (1) with conduit nut (42). (21) Connect quick disconnect terminal (43) to ground strip (13) position 16. (22) Install terminal lug (44) on terminal block (21) position 10 with screw (45). (23) Install crane power cable (46) in junction box (1) with four screws (47), lockwashers (48), and nuts (49). 7-156