TM 9-2320-366-20-3 7-27. M1084/M1086 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT) (11) Install system shutdown solenoid and boom up lockout solenoid cable assembly (24) in junction box (1) conduit nut (25). (12) Connect two quick disconnect terminals (26) to ground strip (13) positions 8 and 2. (13) Install two terminal lugs (27) on terminal block (15) position 28 and terminal block (21) position 12 with two screws (28). (14) Install hoist up solenoid, hoist down solenoid, boom up solenoid, and boom down solenoid cable assembly (29) in junction box (1) with conduit nut (30). 7-154