TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 897 of 1396

TM 9-2320-366-20-3 NOTE Perform steps (13) through (16) on junction boxes that have not had modification kit installed. (13) Install lockout relay (37) and shutdown relay (38) on brackets (39 and 40) with six washers (41), lockwashers (42), and nuts (43). (14) Install brackets (39 and 40) in junction box (2) with six rivets (44). (15) Install shrink tubing (45) over ends of five wires (46) and solder ends on shutdown relay (38) positions 1 through 5. (16) Install shrink tubing (45) over ends of five wires (47) and solder ends on lockout relay (37) positions 1 through 5. Change 1 7-151