TM 9-2320-366-20-3 (12) Disconnect quick disconnect terminal (23) from ground strip (5) position 16. (13) Remove screw (24) from terminal block (7) position 10. (14) Remove conduit nut (25) and left jack cylinder proximity sensor cable (26) from junction box (2). Discard conduit nut. (15) Disconnect quick disconnect terminal (27) from ground strip (5) position 15. (16) Remove two screws (28) from terminal block (7) positions 9 and 14. (17) Remove ten screws (29) from terminal block (12) positions 17 through 26. 7-141