TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 834 of 1396
TM 9-2320-366-20-3  7-92 Change 2  7-14. ELECTRICAL GAGES REPLACEMENT (CONT)  b. Installation.  (1) Remove cover (1) from speedometer (2).  (2) Set dipswitches 3,6,7, and 9 in the down position.  (3) Set dipswitches 1,2,4,5,8, and 10 in the up position.  (4) Position speedometer (2) in instrument panel  assembly (3) with retaining ring (4) and two self  locking nuts (5).  (5) Tighten two self-locking nuts (5) to 9 lb-in. (1 N•m).  (6) Install two protective caps (6) on speedometer (2).  (7) Connect connector PX8 (7) on speedometer  connector (8).  (8) Connect connector clamp (9) on speedometer  connector (8).  c. Follow-On Maintenance.  (1) Install instrument panel assembly (para 7-15).  (2) Check gage(s) operation (TM 9-2320-366-10-1).  End of Task.  CAUTION  Ensure dipswitch settings are correct.  Failure to comply may result in inaccurate  speedometer readings.  NOTE  Perform steps (1) through (3) on  speedometer.  NOTE  Note position of speedometer prior to  installation.  NOTE  Install plastic cable ties as required.