TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 833 of 1396
TM 9-2320-366-20-3  7-14. ELECTRICAL GAGES REPLACEMENT  This task covers:  a. Removal  b. Installation  c. Follow-On Maintenance  INITIAL SETUP  Equipment Conditions  Instrument panel assembly removed for access (para  7-15).  Tools and Special Tools  Tool Kit, Genl Mech (Item 46, Appendix C)  Wrench, Torque, 0-75 lb-in. (Item 90, Appendix B)  Materials/Parts  Ties, Cable, Plastic (Item 69, Appendix D)  Nut, Self-Locking (2) (Item 133, Appendix G)  a. Removal.  NOTE  All electrical gages are removed the same  way. Speedometer shown.  (1) Disconnect connector clamp (1) from speedometer  connector (2).  NOTE  Remove plastic cable ties as required.  (2) Disconnect connector PX8 (3) from speedometer  connector (2).  NOTE  Note position of speedometer prior to  removal.  (3) Remove two protective caps (4), self-locking nuts (5),  retaining ring (6), and speedometer (7) from instrument  panel assembly (8). Discard self-locking nuts.  7-91