TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 677 of 1396

TM 9-2320-366-20-3 WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (10) Apply antiseize compound to threads of radiator draincock (14). (11) Install radiator draincock (14) in radiator (3). (12) Loosen two screws (15) in clamps (16) as far as possible without disengaging screws from D-nuts (17). (13) Unhook clamp tabs (18) from tab windows (19). CAUTION • Clamp tongue must be started in clamp groove. Failure to comply may result in damage to equipment. • Position clamps so that screws will be toward center of vehicle and angled down. (14) Position two clamps (16) on lower coolant hose (20). Change 1 6-23