TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 565 of 1396

TM 9-2320-366-20-3 NOTE Inner and outer charge air cooler to air inlet elbow tubes are installed the same way. Outer charge air cooler to air inlet elbow tube shown. (9) Position hose (19) on charge air cooler (20) with three clamps (21). (10) Position charge air cooler to air inlet elbow tube (2) in hose (19). CAUTION Clamps at charge air cooler end of charge air cooler to air inlet elbow tube must be oriented with screw vertical. Failure to comply will cause interference with bottom of cab. (11) Tighten three clamps (21) to 90-100 lb-in. (7-8 N·m). CAUTION All clamps on engine air intake path must be positioned and tightened correctly. Failure to comply may allow foreign matter into engine air intake and result in engine failure. (12) Position hose (1) on air inlet elbow (5) with clamp (22). (13) Tighten clamps (3 and 22) to 90-100 lb-in. (7-18 N·m). 4-35