TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2019 2-2019 2-2019 2-2019 2-2019 NOTE When checking manifold valve assembly, ensure air pressure in air tanks is 120 psi. Manifold valve assembly cannot be checked if air supply is not available to it. MANIFOLD VALVE ASSEMBLY TEST (1) Position master power switch to on (TM 9-2320-366-10-1). (2) If two mode lights illuminate during deflation: (a) Select a mode that is lower on CTIS ECU (TM 9-2320-366-10-1). (b) Check if manifold valve assembly clicks when no air is escaping from relief valve. (c) If manifold valve assembly clicks and no air escapes at relief valve, replace manifold valve assembly (para 12-7). (3) If two mode lights illuminate during inflation: (a) Select a mode that is higher on CTIS ECU (TM 9-2320-366-10-1). (b) Disconnect air hose at delivery port of manifold valve assembly. (c) Check if manifold valve assembly clicks and no air escapes at delivery port. (d) If no air escapes at delivery port during inflation mode, replace manifold valve assembly (para 12-7).