AIR PRESSURE TEST STE/ICE-R TEST #50 WARNING Wear protective goggles to protect against possible injury from release of high pressure air. Failure to comply may result in injury to personnel. NOTE Tag air hose and connection point prior to disconnecting. (1) Disconnect air hose from actuator listed in Table 2-66. Wrecker Function Solenoid Valves and Actuators. (2) Install test adapter on solenoid valve. (3) Install STE/ICE-R 0-1000 psi transducer on test adapter. (4) Start engine (TM 9-2320-366-10-1). (5) Position WRECKER REMOTE CONTROL switch listed in Table 2-67. Wrecker Function Actuator. (6) Perform STE/ICE-R Test #50 and note reading on STE/ICE-R. (7) If 75 to 120 psi (517 to 827 kPa) is not present, replace air hose (para 23-5). (8) If 75 to 120 psi (517 to 827 kPa) is present, notify DS Maintenance. (9) Shut down engine (TM 9-2320-366-10-1). (10) Drain air tanks (TM 9-2320-366-10-1). (11) Remove STE/ICE-R and test adapter from solenoid valve. (12) Install air hose on actuator. (13) Install front middle and lower panel covers (para 17-20). (14) Install top control panel cover (para 17-20). TM 9-2320-366-20-3 Change 1 2-2433/(2-2434 Blank)