TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 469 of 1396
NOTE WARNING Wear protective goggles to protect against possible injury from release of high pressure air. Failure to comply may result in injury to personnel. AIR PRESSURE TEST STE/ICE-R TEST #50 (1) Remove wrecker control panel top cover (para 14-4). (2) Disconnect air hose from input fitting of 30K winch manifold assembly. (3) Connect air hose to M1089 30K winch pneumatic test adapter. (4) Install STE/ICE-R 0-1000 PSI transducer in M1089 30K winch pneumatic test adapter. (5) Start engine (TM9-2320-366-10-1) and allow vehicle to build air pressure. (6) Perform STE/ICE-R Test #50 and note reading on STE/ICE-R. (7) If 75-120 PSI (518-827 kPa) is not present, replace air hose (para 23-5). (8) Shut down engine (TM 902320-366-10-1). (9) Drain air tanks (TM9-2320-366-10-1). (10) Remove STE/ICE-R 0-1000 PSI transducer from M1089 30K winch pneumatic test adapter. (11) Disconnect air hose from M1089 30K winch pneumatic test adapter. TM 9-2320-366-20-3 Change 1 2-2428.5 Tag air hose and connection point prior to disconnecting