TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 463 of 1396
AIR PRESSURE TEST STE/ICE-R TEST #50 Tag air hose and connection piont prior to disconnecting NOTE WARNING Wear protective goggles to protect against possible injury from release of high pressure air. Failure to comply may result in injury to personnel. TM 9-2320-366-20-3 (13) Disconnect air hose from M1089 30K winch pneumatic test adapter. (14) Connect air hose to RH 30K winch free spool 90 degree fitting. Change 1 2-2427 (1) Disconnect air hose from RH 30K winch freespool input 90 degree fitting. (2) Install tube nipple on M1089 30K winch pnematic test adapter. (3) Connect air hose to M1089 30K winch pneumatic test adapter. (4) Start engine (TM 9-2320-366-10-1) and allow vehicle to build air pressure. (5) Position MAIN WINCH RH FREESPOOL switch to ON. (6) Perform STE/ICE-R Test #50 and note reading on STE/ICE-R. (7) If 75-120 PSI (518-827 kPa) is not present, replace air hose (para 23-5). (8) If 75-120 PSI (518-827 kPa) is present, notify DS Maintenance, RH 30K winch assembly is faulty. (9) Shutdown engine (TM 9-2320-366-10-1). (10) Drain air tanks (TM 9-2320-366-10-1). (11) Positon MAIN WINCH RH FREESPOOL switch to OFF. (12) Remove STE/ICE-R 0-1000 PSI transducer from M1089 30K winch pneumatic test adapter.