TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 CONTINUITY TEST CONTINUITY TEST (1) Disconnect winch remote control cable from winch remote control connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to right middle post of out solenoid. (4) Connect negative (-) probe of multimeter to winch remote control connector pin B and note reading on multimeter. (5) If continuity is not present, replace power harness (para 20-60). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to winch remote control cable socket A. (3) Connect negative (-) probe of multimeter to winch remote control cable socket B. (4) Position winch remote control switch to out and note reading on multimeter. (5) If continuity is not present, replace winch remote control cable. (6) If continuity is present, replace LMHC winch assembly (para 20-60). (7) Connect winch remote control cable to winch remote control connector. (8) Install cover on base plate with 18 screws. 2-2407/(2-2408 Blank) 2-2407/(2-2408 Blank) 2-2407/(2-2408 Blank) 2-2407/(2-2408 Blank) 2-2407/(2-2408 Blank)