TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 41 of 1396
TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2011 2-2011 2-2011 2-2011 2-2011 Two steady mode lights are an indication that the CTIS has discontinued operation because a particular inflate or deflate sequence has taken longer than limits allow (40 minutes for inflate; 20 minutes for deflate). The CTIS may still operate including modes that are lit, by manually pressing the desired mode. NOTE Two steady mode lights indicate that CTIS is shut off with air pressure between modes. To perform deflate or inflate checks throughout this task, it may be necessary to perform the opposite function first so that a desired mode selection is available. SOAPY WATER LEAK TEST (1) Remove kick panel (para 16-3). (2) Apply soapy water solution to supply air hose fitting at manifold valve assembly. (3) Check for air escaping at manifold valve assembly, indicated by air bubbles. (4) Remove two screws and washers from front grille. (5) Remove screw and washer from front grille. (6) Remove front grille from cab. (7) Apply soapy water solution to supply air hose from wet tank at cab floor. (8) Check for air escaping at cab floor fittings, indicated by air bubbles.