TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 403 of 1396

TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2391 2-2391 2-2391 2-2391 2-2391 CONTINUITY TEST (1) Disconnect LMHC control power cable from LMHC winch assembly power connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to one end of LMHC control box power cable socket A. (4) Connect negative (-) probe of multimeter to other end of LMHC control box power cable socket A and note reading on multimeter. (5) If continuity is not present, replace LMHC control box power cable. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to LMHC control box power cable socket B. (3) Connect negative (-) probe of multimeter to LMHC control box power cable socket B and note reading on multimeter. (4) If continuity is not present, replace LMHC control box power cable. CONTINUITY TEST