TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 401 of 1396
TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2389 2-2389 2-2389 2-2389 2-2389 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to one end of LMHC control box circuit breaker. (3) Connect negative (-) probe of multimeter to other end of LMHC control box circuit breaker. (4) Position LMHC control box circuit breaker to ON and note reading on multimeter. (5) If continuity is not present, replace LMHC control box circuit breaker (para 20-67). (6) Position LMHC control box circuit breaker to OFF. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to LMHC control box circuit breaker outlet post. (3) Connect negative (-) probe of multimeter to LMHC control box connector pin A and note reading on multimeter. (4) If continuity is not present, replace wire 592 (para 20-70). (5) Close cover on LMHC control box. (6) Connect LMHC control box power cable to LMHC control box connector.