TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 399 of 1396
TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2387 2-2387 2-2387 2-2387 2-2387 CONTINUITY TEST CONTINUITY TEST (1) Open cover on LMHC control box. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to NATO plug positive (+) terminal. (4) Connect negative (-) probe of multimeter to LMHC control box circuit breaker supply post and note reading on multimeter. (5) If continuity is not present, replace wire 170 (para 20-70). (1) Disconnect LMHC control box power cable from LMHC control box connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to NATO plug negative (-) terminal. (4) Connect negative (-) probe of multimeter to LMHC control box connector pin B and note reading on multimeter. (5) If continuity is not present, replace wire 150 (para 20-70). (6) Install cover and retainer on NATO plug with eight screws.