TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 397 of 1396
TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2385 2-2385 2-2385 2-2385 2-2385 CONTINUITY TEST CONTINUITY TEST (1) Remove eight screws, cover, and retainer from NATO plug. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to NATO plug pin. (4) Connect negative (-) probe of multimeter to NATO plug positive (+) terminal lug and note reading on multimeter. (5) If continuity is not present, replace NATO plug (para 20-70). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to NATO plug outer wall. (3) Connect negative (-) probe of multimeter to NATO plug negative (-) terminal lug and note reading on multimeter. (4) If continuity is not present, replace NATO plug (para 20-70).