TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2382 2-2382 2-2382 2-2382 2-2382 1. YES NO Engine starts. POSSIBLE PROBLEMS START WARNING Read WARNING on following page. KNOWN INFO TEST OPTIONS Voltage Test or STE/ICE-R #89 REASON FOR QUESTION Faulty NATO power cable. Faulty NATO plug. Faulty wire 150. Faulty circuit breaker. Faulty wire 170. Faulty wire 592. Faulty power cable. Faulty power harness. Faulty out solenoid. Faulty in solenoid. Faulty LMHC winch assembly. Faulty winch cable. Is 24 vdc present across NATO power receptacle? If 24 vdc is not present, NATO power cable is faulty. x19. LIGHT MATERIAL HANDLING CRANE (LMHC) DOES NOT OPERATE Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P Replace NATO power cable (para 7-70). INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Personnel Required (2)