TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 389 of 1396

TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2377 2-2377 2-2377 2-2377 2-2377 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Disconnect connector clamp from connector J39. (3) Disconnect connector J39 from connector P39. (4) Connect positive (+) probe of multimeter to connector P921-A. (5) Connect negative (-) probe of multimeter to connector J39-2 and note reading on multimeter. (6) If continuity is not present, repair wire 32 (para 2-45) or replace troop transport alarm cable assembly (para 20-69). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P921-C. (3) Connect negative (-) probe of multimeter to connector J39-1 and note reading on multimeter. (4) If continuity is not present, repair wire 3028 (para 2-45) or replace troop transport alarm cable assembly (para 20-69). (5) Connect connector P921 to connector J921.