TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 378 of 1396

INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-2) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 46, Appendix C) Personnel Required (2) 1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 YES NO TEST OPTIONS REASON FOR QUESTION Go to step 2 of this fault. POSSIBLE PROBLEMS 2-2304 Change 2 x7. NO POWER TO MOBILE TRACKING SYSTEM (MTS) Circuit breaker CB10 is not tripped. Contact supervisor, Mobile Tracking System (MTS) troubleshooting needs to be performed. Is 24 VDC present at terminal lug TL1? Faulty circuit breaker CB10. Faulty digitization rack power supply. Faulty Mobile Tracking System (MTS). START TM 9-2320-366-20-3 If 24 VDC is not present, go to step 2 of this fault. If 24 VDC is present, perform Mobile Tracking System (MTS) troubleshooting.