TEST OPTIONS YES NO REASON FOR QUESTION 2. Continuity Test or STE/ICE-R Test #91 Perform Special Purpose Kit Troubleshooting task x1. No Power to Digitization Rack. TEST OPTIONS Replace circuit breaker CB8 (para 20-80). 2-2302 Change 2 Is continuity present through circuit breaker CB8? x6. NO POWER TO SINGLE CHANNEL GROUND & AIR BORNE RADIO (SINCGARS)/FORCE XXI BATTLE COMMAND BRIGADE OR BELOW (FBCB) (CONT) Faulty circuit breaker CB8. Faulty digitization rack power supply. POSSIBLE PROBLEMS Circuit breaker CB8 is not tripped. TM 9-2320-366-20-3 If continuity is not present, circuit breaker CB8 is faulty. If continuity is present, perform Special Purpose Kits Troubleshooting task x1. No Power to Digitization Rack.