TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 372 of 1396
TM 9-2320-366-20-3 TEST OPTIONS YES NO REASON FOR QUESTION 2. Continuity Test or STE/ICE-R Test #91 Perform Special Purpose Kit Troubleshooting task x1. No Power to Digitization Rack. 2-2298 Change 2 TEST OPTIONS x5. NO POWER TO DRIVER VISUAL ENHANCEMENT (DVE) (CONT) Replace circuit breaker CB6 (para 20-80). If continuity is not present, circuit breaker CB6 is faulty. If continuity is present, perform Special Purpose Kits Troubleshooting task x1. No Power to Digitization Rack. Is continuity present through circuit breaker CB6? POSSIBLE PROBLEMS Faulty circuit breaker CB6. Faulty digitization rack power supply. Circuit breaker CB6 is not tripped.