TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 370 of 1396

INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-2) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 46, Appendix C) Personnel Required (2) 1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 YES NO TEST OPTIONS REASON FOR QUESTION Go to step 2 of this fault. x5. NO POWER TO DRIVER VISUAL ENHANCEMENT (DVE) Is 24 VDC present at terminal lug TL3? 2-2296 Change 2 Contact supervisor, Driver Visual Enhancement (DVE) troubleshooting needs to be performed. START TM 9-2320-366-20-3 If 24 VDC is not present, go to step 2 of this fault. If 24 VDC is present, perform Driver Visual Enhancement (DVE) troubleshooting. POSSIBLE PROBLEMS Circuit breaker CB6 is not tripped. Faulty circuit breaker CB6. Faulty digitization rack power supply. Faulty Driver Visual Enhancement (DVE) system.