TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 368 of 1396
2-2294 Change 2 TEST OPTIONS YES NO TEST OPTIONS 2. Continuity Test or STE/ICE-R Test #91 Replace circuit breaker CB7 (para 20-80). Perform Special Purpose Kit Troubleshooting task x1. No Power to Digitization Rack. REASON FOR QUESTION Is continuity present through circuit breaker CB7? If continuity is not present, circuit breaker CB7 is faulty. If continuity is present, perform Special Purpose Kits Troubleshooting task x1. No Power to Digitization Rack. TM 9-2320-366-20-3 x4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER (PLGR) (CONT) Circuit breaker CB7 is not tripped. POSSIBLE PROBLEMS Faulty circuit breaker CB7. Faulty digitization rack power supply.