TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 366 of 1396

1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 YES NO TEST OPTIONS REASON FOR QUESTION Go to step 2 of this fault. 2-2292 Change 2 START TM 9-2320-366-20-3 Circuit breaker CB7 is not tripped. POSSIBLE PROBLEMS Faulty circuit breaker CB7. Faulty digitization rack power supply. Faulty Precision Lightweight Global Positioning System Receiver (PLGR). Is 24 VDC present at terminal lug TL9? If 24 VDC is not present, go to step 2 of this fault. If 24 VDC is present, perform Precision Lightweight Global Positioning System Receiver (PLGR) troubleshooting. Contact supervisor, Precision Lightweight Global Positioning System Receiver (PLGR) troubleshooting needs to be performed. INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-2) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 46, Appendix C) Personnel Required (2) x4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER (PLGR)