TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 362 of 1396

INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-2) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 46, Appendix C) Personnel Required (2) 1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 YES NO TEST OPTIONS REASON FOR QUESTION Go to step 2 of this fault. 2-2288 Change 2 x3. NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS) Contact supervisor, Ehanced Position Location Reporting System (EPLRS) troubleshooting needs to be performed. START TM 9-2320-366-20-3 POSSIBLE PROBLEMS Circuit breaker CB5 is not tripped. Faulty circuit breaker CB5. Faulty digitization rack power supply. Faulty Enhanced Position Location Reporting System (EPLRS). Is 24 VDC present at terminal lug TL8? If 24 VDC is not present, go to step 2 of this fault. If 24 VDC is present, perform Enhanced Position Location Reporting System (EPLRS) troubleshooting.