TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 360 of 1396

2-2286 Change 2 TEST OPTIONS YES NO TEST OPTIONS REASON FOR QUESTION 3. Voltage Test or STE/ICE-R Test #89 WARNING Read WARNING on following page. Replace Power Distribution Panel (PD2) (para 20-81). Replace power cable from terminal lug TL15 to terminal lug TL22 (para 20-81). x2. NO POWER TO MOBILE TRACKING SYSTEM (MTS) SENSE (CONT) TM 9-2320-366-20-3 Circuit breaker CB1 is not tripped. Circuit breaker CB1 OK. POSSIBLE PROBLEMS Faulty power cable from terminal lug TL15 to terminal lug TL22. Faulty Power Distribution Panel (PD2). Is 24 VDC present at terminal lug TL15? If 24 VDC is not present, power cable from terminal lug TL15 to terminal lug TL22 is faulty. If 24 VDC is present, Power Distribution Panel (PD2) is faulty.