TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 352 of 1396
x1. NO POWER TO DIGITIZATION RACK (CONT) TEST OPTIONS REASON FOR QUESTION YES NO TEST OPTIONS Voltage Test or STE/ICE-R Test #89 WARNING Read WARNING on following page. 4. Circuit breaker CB11 not tripped. Power cable from terminal lug TL24 to terminal lug TL20 OK. POSSIBLE PROBLEMS 2-2278 Change 2 Replace power cable from terminal TL23 to terminal TL16 (para 20-81). If 24 VDC is not present, circuit breaker CB11 is faulty. If 24 VDC is present, power cable from terminal lug TL23 to terminal lug TL16 is faulty. Is 24 VDC present at terminal lug TL23? Replace circuit breaker CB11 (para 20-81). Faulty circuit breaker CB11. Faulty power cable from terminal lug TL23 to terminal lug TL16. TM 9-2320-366-20-3