TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 350 of 1396
x1. NO POWER TO DIGITIZATION RACK (CONT) TEST OPTIONS REASON FOR QUESTION YES NO TEST OPTIONS POSSIBLE PROBLEMS 3. 2-2276 Change 2 Circuit breaker CB11 not tripped. Voltage Test or STE/ICE-R Test #89 WARNING Read WARNING on following page. Replace power cable from terminal lug TL24 to terminal lug TL20 (para 20-81). TM 9-2320-366-20-3 Faulty circuit breaker CB11. Faulty power cable from terminal lug TL24 to terminal lug TL20. Faulty power cable from terminal lug TL23 to terminal lug TL16. Is 24 VDC present at terminal lug TL24? If 24 VDC is not present, power cable from terminal lug TL24 to terminal lug TL20 is faulty.