TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 346 of 1396

x1. NO POWER TO DIGITIZATION RACK INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-2) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 46, Appendix C) Personnel Required (2) TEST OPTIONS POSSIBLE PROBLEMS Nothing. 1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where troubleshooting continues. YES NO Go to step 2 of this fault. Go to step 5 of this fault. START TM 9-2320-366-20-3 2-2272 Change 2 Is 24 VDC present at terminal lug TL16? Circuit breaker CB11 tripped. Faulty circuit breaker CB11. Faulty power cable from terminal lug TL24 to terminal lug TL20. Faulty power cable from terminal lug TL23 to terminal lug TL16. Faulty power cable from terminal lug TL18 to terminal block TB2. Faulty Power Distribution Panel (PD1).