TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 341 of 1396

TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2267 2-2267 2-2267 2-2267 2-2267 WARNING Drop hydraulic pressure to zero before disconnecting any hydraulic line. Failure to comply may result in injury to personnel. Wear approved eye protection when performing pressure checks. Failure to comply may result in oil getting into eyes. If oil contacts eyes, seek medical attention immediately. Fuel and oil are slippery and can cause falls. Wipe up spilled fuel or oil with rags. Failure to comply may result in injury to personnel. HAND PUMP TEST (1) Disconnect hand pump delivery line from elbow at hand pump. (2) Place drain pan under port at pump to catch hydraulic fluid. (3) Pump hand pump (TM 9-2320-366-10-1). (4) Check if hydraulic fluid pumps out of port with each stroke. (5) If little or no hydraulic fluid pumps out, hand pump is faulty. (6) Connect delivery line to elbow at hand pump. (7) Remove drain pan.