TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2266 2-2266 2-2266 2-2266 2-2266 KNOWN INFO 1. TEST OPTIONS YES NO START REASON FOR QUESTION Hydraulic oil level OK. Hydraulic lines and fittings OK. All functions operate with PTO engaged. POSSIBLE PROBLEMS Hand Pump Test Faulty input check valve. Faulty hand pump. Faulty check valve or hand pump will prevent manual operation of crane. Does hand pump build pressure? WARNING Read WARNING on following page. Notify DS Maintenance. Notify DS Maintenance. w10. M1089 MATERIAL HANDLING CRANE (MHC) HAND PUMP DOES NOT WORK INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Pan, Drain (Item 24, Appendix C) Goggles, Industrial (Item 15, Appendix C) Materials/Parts Rag, Wiping (Item 50, Appendix D)