TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download
Page 317 of 1396
TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 TM 9-2320-366-20-3 2-2247 2-2247 2-2247 2-2247 2-2247 WARNING Wear approved eye protection when performing pressure checks. Failure to comply may result in oil getting into eyes. If oil contacts eyes, seek medical attention immediately. Fuel and oil are slippery and can cause falls. Wipe up spilled fuel or oil with rags. Failure to comply may result in injury to personnel. NOTE Adapter and tee kit used in this STE/ICE test, includes: (a) 3/4" swivel nut run tee. (b) 1/2" internal pipe, 3/4" 37 degree flare swivel adapter. PRESSURE TEST Drop hydraulic pressure to zero before disconnecting any hydraulic hoses, tubes and fittings. Failure to comply may result in injury to personnel. (1) Place drain pan under vehicle. (2) Disconnect hydraulic pressure hose from lower main pressure tube. (3) Connect STE/ICE-R, with adapter and tee, between hydraulic pressure hose and tube. (4) Start engine (TM 9-2320-366-10-1). (5) Position PTO switch to on (TM 9-2320-366-10-1). (6) Perform STE/ICE-R test #51 (TM 9-4910-571-12&P) and note pressure reading is between 2400-3000 psi (16,548- 20,685 kPa). (7) If pressure noted in step (6) is below 2400 psi (16,548 kPa), notify DS Maintenance. (8) If pressure noted in step (6) is between 2400-3000 kPa) notify DS Maintenance. (9) Position PTO switch to off (TM 9-2320-366-10-1). (10) Shut down engine (TM 9-2320-366-10-1). (11) Disconnect STE/ICE-R, tee, and adapter from pressure line. (12) Connect hydraulic pressure hose to lower main pressure tube. (13) Tighten hydraulic hose to 36-39 lb-ft (49-53 N·m).