TM-9-2320-366-20-3 MTV Unit Maintenance Manual M1083 Series - Volume 3 Download

Page 270 of 1396

TM 9-2320-366-20-3 KNOWN INFO TEST OPTIONS YES REASON FOR QUESTION Pressure Test or STE/ICE-R Test #51 NO If 2,500-4,000 psi (17,238- 27,580 kPa) is present, suspension release tee fitting is faulty. Replace suspension release tee fitting (para 19-12). 7. Go to step 8 of this fault. 2-2230.12 Change 1 Other hydraulic manifold functions OK. Hydraulic hoses free from leaks. Hydraulic hoses 508 and 510 OK. Suspension compression tee fitting OK. Air/hydraulic manifold OK. Hydraulic hose 512 OK. Hydraulic hose 513 OK. POSSIBLE PROBLEMS Faulty suspension release tee fitting. Faulty suspension cylinder(s). Faulty hydraulic hose(s) 509 and/or 511. Is 2,500-4,000 psi (17,238-27,580 kPa) present at suspension release tee fitting input ports? u2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)