TM 9-2320-366-20-3 PRESSURE TEST Change 1 2-2230.7 (1) Disconnect hydraulic hose 512 from suspension compression tee fitting input port. (2) Connect STE/ICE-R between hydraulic hose 512 and suspension compression tee fitting input port. (3) Start engine (TM 9-2320-366-10-1). (4) Position SUSPENSION knob to RAISE (TM 9-2320-366-10-1). (5) Position FUNCTION SELECT knob to SUSPENSION (TM 9-2320-366-10-1). (6) Push and hold PUMP plunger button (TM 9-2320-366-10-1) and perform STE/ICE-R Test #51. (7) If 2,500-4,000 psi (17,238-27,580 kPa) is not present, go to step 5 of this fault. (8) If 2,500-4,000 psi (17,238-27,580 kPa) is present, replace suspension compression tee fitting (para 19-12). (9) Disconnect STE/ICE-R from hydraulic hose 512 and suspension compression tee fitting input port. (10) Connect hydraulic hose 512 to suspension compression tee fitting input port.